. How to Use Your National Cash Register Class 500 Follow Directions It is important to follow direction for the use of this register. Often a register is thought to need some repairs or adjustment when the trouble could be remedied by the following directions.

Et 500 manual

CONTENTS Follow Directions Locks Nos. 1, 2, 3 and 5 Locks Nos. 6 and 8 Clerk’s Locks To Operate the Register The Key Release Lever Drawer Release Lever Credit System Keys Clerks' and Customers, Special Counters To Put on Check Paper Roll To Supply a New Roll of Detail Paper To Ink the Felt Inking Rolls and Pads To Ink the Pelt Pad. Directions For Use and Care of Clan 500 National Cash Registers When register is taken from packing case place it on a solid level counter. Unlock register with keys tied to front which are numbered 1, 2, 3, 5, 6 and 8. 6 This lock is attached to lid over special key counters at the right of the special keys, and the flash covering the special and customer counters on the lower front of register.

PEGANOTAS TRITON 5 COLORES 500 hojas. Precio con IVA $ 10.300,00. Comparar >> Mas info >. Manual de proveedores Makro; Reglamento Makro Ahorro. Lock for manual release figure 3.1 motor unit coimplete what’s in the box. Technical data et-500 12v et-500 acdc maximum absorbed current @ 220v ac supply. Elco elco elco futura a810 instrucciones elco futura a810 instrucciones elco data et-500 uso istruzion elco data et-500 uso istruzion elco data ax-100 uso uso instr.

Et 500 Manual

8 The Flash over the reel total-adding counters is operated by key No. This lock is located near the lower left corner of the cabinet over these counters.

The Key Release Lever This device is placed below the first row of keys and is to release any of the keys in case they have been pressed by mistake. This lever cannot be operated unless the operating handle is in the home position. To Put on Check Paper Roll Unlock Lock No. 5, push down catch and remove hood. Remove plate in front of check paper roll by lifting up and off. Turn knob “G” until the word “off” is in correct reading position. Place the roll of paper on the stud so that end of paper unwinds from the back.

Elco

Use the purple ink on the ink rolls ONLY and not on the pads. Do not use any ink except that which is sent with the register or purchased from The National Cash Register Co. Other inks dry or gum and prove very unsatisfactory. To Reset the Clerks' Counters to Zero Unlock Lock No. Put the small resetting key in the hole on the left side of the register (see cut in front), and turn key from you until it comes to a stop, and the wheels show zero.

Remove the key and move the lever to the next position. To Change the Date (See cut in front.) The three thumb-nuts, “D,” “E” and “F,” control the dating wheels. The outside or longest thumb-nut “F” controls the months; the next or middle thumb-nut “E” is numbered from one to three, and prints the 10th, 20th and 30th days of the month; the shortest thumb-nut “D” represents the days from 0 to 9. Autographic Attachment To supply autograph with new roll of paper re move cabinet by lifting up and off.

Remove the mechanism by lifting up high enough to clear the pins in the cabinet base. Place autograph in the right hand with the knurled wheel to the right; remove the lock nut at the left end of supply roll by turning TOWARD you. To remove back printing cylinder turn knob “G” until the word “OFF” is in correct reading position. Raise lever “Z” and remove cylinder by pulling to the right.

This cylinder is carried by a stud having an eccentric sleeve held in position by the clutch “R.” This sleeve governs the impression of the back printing cylinder and is regulated by loosening, the screw in clutch “R”. Directions for Electrically Operated Registers It is advisable to first operate the register by means of the handle before making the electric connection. This is advised to enable the user to become familiar with the various devices and operations as described in this book.

When operating register electrically, remove handle and put in its place handle stud collar and replace screw. To Put in Fuse 'The fuse is located in the terminal block at the lower end of the motor. Should the register be stopped in its operation by any accidental cause, the fuse will burn out unless the current is turned off at once. When the fuse is burned out, the circle on the side will be blackened, thus indicating that new fuse should be put in. Illuminated Indication On registers, having this feature, it is important that lamps of the proper voltage be used. Registers having four lamps are wired with the two lamps on each side in series, in which case the lamp voltage of each lamp should be one-half the maximum line voltage.

Registers having but two lamps, controlled by a time limit switch, are wired with the lamps in parallel, in which case the lamp, voltage of each lamp should equal the maximum line voltage. In ordering supplies amounting to less than, $3, please remit payment in advance. This is requested in order to avoid the necessity of opening a large number of ledger accounts for small items. We receive thousands of small orders for supplies which, if charged on open account, would entail expenditures of a vast amount of time and labor. In case the register is in need of adjustment or repair, do not allow anyone excepting our authorized representative to make any adjustment or repair, as persons not familiar with the construction of the register are likely to damage the mechanism. The National Cash Register Co., Dayton, Ohio, U. Form 658 10-65805-91 Page 18.

United a319 aerosoft. Text on left reads: Hole for resetting wrench “K” Slide counter “M” Lock No. 8 Text on top pointing to the window reads: Opening for counters “H” This cut shows the covering over the multiple counters. “H” represents the opening through which statements of the counters cab be taken. Arrows on left are: “C” and A”” and “Ink Pads” Right side arrows are: “I”, “R”, “Z”, “Ink Roll”, “B” Arrows across the bottom are: “D”, “E”, “F”, “C”, and “O” Page 20. Text from top to bottom is: Turn to zero counter Lock No. 2 Clerks’ counter lever Opening for turn to zero key Lock No. 5 Release key Page 21.

The National Cash Register Co., Dayton, Ohio. President John H.